Product Description
Inner Conductor: solid or stranded Bare Copper
Insulation: Foam PE or XLPE(cross linked PE)
Outer Conductor: Bare Copper braiding, various of coverage 
Or    CU/PET/CU (copper-PET-copper laminated) foil and Bare Copper or Tinned Copper braiding , various of coverage
Or  triple shield AL/PET/AL(aluminum-PET-aluminum) foil , and Bare Copper or Tinned Copper braiding various of coverage, and AL/PET/AL(aluminum-PET-aluminum) foil;
Jacket: PVC, FRPVC, PE, LSZH(Low Smoke & Zero Halogen) available;
 
RoHS Complaints(2002/95/EC)
 
Application
For transmitter and receiver installations in radio communications as well as in the entire field of commercial radio-frequency technology and electronics. And it is suitable for mobile applications and as connecting cable for measuring instruments.
 
                                                                                                                                                                                                                        RF Cables
| 
 Part 
No.  | 
 Specifications  | 
 Inner Conductor  | 
 Dielectric  | 
 Outer Conductor  | 
 Jacket  | 
 Specification 
Sheet  | 
| 
 MTR.  | 
 mm  | 
 Foil  | 
 Braid  | 
 Coverage  | 
 MTR.  | 
 Nom. 
Dia.  | 
| 
 mm  | 
| 
 114501  | 
 2XCH 0.3L /0.87 
(C-50-1-1)  | 
 BC 
stranded  | 
 7/0.10  | 
 XLPE  | 
    | 
 BC  | 
 94%  | 
 FRNC  | 
 2.0  | 
      | 
| 
 114502  | 
 2XCH 0.5L /1.5 
(C-50-2-1)  | 
 BC 
stranded  | 
 7/0.16  | 
 XLPE  | 
    | 
 BC  | 
 95%  | 
 FRNC  | 
 2.80  | 
      | 
| 
 114503  | 
 02Y(St)C(st)H 0.96L/2.6AF 
(C-50-3-1)  | 
 BC 
stranded  | 
 7/0.32  | 
 Foam PE  | 
 Al/PET/AL+93%TC+Al/PET/Al  | 
 FRNC  | 
 4.80  | 
      | 
| 
 114504  | 
 02Y(St)CY../..H1.0/2.95AF  | 
 BC  | 
 1/1.04  | 
 Foam PE  | 
 Al/PET/Al  | 
 TC  | 
 96%  | 
 PVC/FRNC  | 
 5.0  | 
      | 
| 
 114505  | 
 02Y(St)CY 1.35L/3.6 OR 
02Y(St)C2Y 1.35L /3.6  | 
 BC 
stranded  | 
 7/0.45  | 
 Foam PE 
   | 
 Al/PET/Al  | 
 TC  | 
 86%  | 
 PVC/PE 
   | 
 5.40  | 
      | 
| 
 114506  | 
 02Y(St)C2Y 1.4/3.8AF  | 
 BC  | 
 1/1.42  | 
 Foam PE  | 
 Al/PET/Al  | 
 TC  | 
 86%  | 
 FRNC  | 
 6.10  | 
      | 
| 
 114507  | 
 02Y(St)C2Y 1.85L/5.0CF  | 
 BC  | 
 19/0.37  | 
 Foam PE  | 
 CU/PET/CU  | 
 BC  | 
 80%  | 
 PE  | 
 7.30  | 
      | 
| 
 114508  | 
 02Y(St)C(St)H 2.6 /7.3AF  | 
 BC  | 
 1/2.61  | 
 Foam PE  | 
 Al/PET/Al +96%TC+Al/PET/Al  | 
 FRNC  | 
 10.30  | 
      | 
| 
 114509  | 
 02Y(St)C2Y 2.7 /7.3AF  | 
 BC  | 
 1/2.71  | 
 Foam PE  | 
 Al/PET/Al+91%TC+Al/PET/Al  | 
 PE  | 
 10.30  | 
      | 
| 
 114510  | 
 02Y(St)C2Y 2.7 /7.3CF  | 
 BC  | 
 1/2.71  | 
 Foam PE  | 
 CU/PET/CU +80%BC  | 
 PE  | 
 10.30  | 
      | 
| 
 114511  | 
 02Y(St)C(St)H 4.2/11.5AF (CK50)  | 
 BC  | 
 1/4.22  | 
 Foam PE  | 
 Al/PET/Al+86%TC+Al/PET/Al  | 
 FRNC  | 
 15.10  | 
      | 
| 
 114512  | 
 02Y(St)C(St)H 2.25L/6.1AF 
(C-50-6-1)  | 
 BC 
stranded  | 
 7/0.75  | 
 Foam PE 
   | 
 Al/PET/Al+92%TC+Al/PET/Al  | 
 FRNC  | 
 10.10  | 
      |