Product Description
Rated Voltage:300V, Rated Temperature:200°C
Conductor: tinned, stranded or solid copper, min.26AWG 
Insulation: silicone rubber;.
Braid: color-coded fiber glass
Passes UL VW-1 vertical flame test.
Resistant to heat and cold.
 
Application
For internal wiring of electrical equipment in high temperature condition.
 
                                                                                                                                                                                           UL 3122  300V  200°C
| 
 Part No.  | 
 Conductor 
type  | 
 Conductor  | 
 Jacket  | 
 Max 
Resistance 
At 20°C  | 
 Max Conductor 
Resistance 
At 20°C  | 
 Dielectric 
Strength 
AC 1min  | 
 Specification 
Sheet 
   | 
| 
 Spec  | 
 No./mm  | 
 Nom. Dia.  | 
 Nom. Thick.  | 
 Nom. Dia  | 
| 
 AWG  | 
 mm  | 
 mm  | 
 mm  | 
 mm  | 
 Ω /KM  | 
 MΩ.KM  | 
 V  | 
| 
 211001  | 
 Stranded 
Conductor  | 
 26  | 
 7/0.16  | 
 0.48  | 
 0.60  | 
 1.68  | 
 139.73  | 
 139.73  | 
 1500  | 
      | 
| 
 211002  | 
 24  | 
 11/0.16  | 
 0.61  | 
 0.60  | 
 1.81  | 
 93.3  | 
 93.3  | 
      | 
| 
 211003  | 
 22  | 
 17/0.16  | 
 0.76  | 
 0.65  | 
 2.06  | 
 55.0  | 
 55.0  | 
      | 
| 
 211004  | 
 20  | 
 26/0.16  | 
 0.94  | 
 0.65  | 
 2.24  | 
 34.6  | 
 34.6  | 
      | 
| 
 211005  | 
 18  | 
 41/0.16  | 
 1.18  | 
 0.65  | 
 2.48  | 
 21.8  | 
 21.8  | 
      | 
| 
 211006  | 
 16  | 
 26/0.254  | 
 1.49  | 
 0.65  | 
 2.79  | 
 13.7  | 
 13.7  | 
      | 
| 
 211007  | 
 14  | 
 41/0.254  | 
 1.88  | 
 0.65  | 
 3.18  | 
 8.62  | 
 8.62  | 
      | 
| 
 211008  | 
 12  | 
 65/0.254  | 
 2.37  | 
 0.90  | 
 4.17  | 
 5.43  | 
 5.43  | 
      | 
| 
 211009  | 
 10  | 
 105/0.254  | 
 3.40  | 
 0.90  | 
 5.20  | 
 3.41  | 
 3.41  | 
      |